Discharging Bars
R50 & R51

R50 – Discharging Bar with fixed connection
R51 – Discharging Bar with plug-type connection
Advantages: ultimate discharge range and hence enhanced depth effect, high active discharge power through isolated ground conductors, high safety standards through passive discharging power with deactivated power supplies, safety through function and malfunction monitoring in connection with the appropriate power supply, continuous assembly slotting guarantees flexible installation, no health hazards from electric shocks when making contact with the tips, no damage to the bars in case of tip short circuit, fixed or detachable connection of the high voltage cable, axial and radial design (radial connection rotatable by 360°), max. active length 3,915 mm, grip spacing of tips 15 mm, max. operating voltage R50: 8 kV AC, R51: 5 kV AC.
L50
Air Channel L50 as support of R50/R51 discharging bars
Air channel for surface cleaning support,
axial, radial or side access air connection,
max. length 3,990 mm, air outlet nozzles 90° or 28°.
EXR5C

EXR5C – Discharging Bar for the EX zones
Advantages: Approval for the use in EX zones according to BAS98ATEX2179X, ultimate discharge range and hence enhanced depth effect, high active discharge power through isolated ground conductors, high safety standards through passive discharging power with deactivated power supplies, safety through function and malfunction monitoring in connection with the appropriate power supply, continuous assembly slotting guarantees flexible installation, no health hazards from electric shocks when making contact with the tips, no damage to the bars in case of tip short circuit, fixed connection of the high voltage cable, axial and radial design (radial connection rotatable by 360°), max. active length 3,915 mm, grip spacing of the tips 15 mm, max. operating voltage 5 kV AC.
R45
R45 – Discharging Bar until max. 6 kV at 1600 mm active length
Advantages: ultimate discharge range and hence enhanced depth effect, high active discharge power through isolated ground conductors, high safety standards through passive discharging power with deactivated power supplies, safety through function and malfunction monitoring in connection with the appropriate power supply, flexible installation, no health hazards from electric shocks when making contact with the tips, no damage to the bars in case of tip short circuit, fixed connection of the high voltage cable, axial design, max. active length 1,600 mm, grip spacing of the tips 15 mm, max. operating voltage 6 kV AC.
R44LS
R44LS – Discharging Bar with rear air channel
Single-row discharging bar with integrated air knife with air circulation of the gas discharge, max. active length 1,995 mm, grip spacing of the tips 15 mm.